Sharp SD-AT1000W Spécifications Page 50

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 292
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 49
Section-2 Installation
October 17, 2013
2‐8
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypower priortoservicing. 888‐2693‐004
Caution
BE CERTAIN THAT THE INSULATION ON EACH AC SUPPLY CABLE HAS
BEEN SUFFICIENTLY CUT BACK TO ALLOW FULL CONTACT BETWEEN THE
CONNECTOR BLOCK AND THE COPPER CABLE. FAILURE TO REMOVE THE
INSULATION MAY RESULT IN HEATING AND FAILURE OF THE
CONNECTION.
STEP 5 Connecttheincomingsafetygroundwiretogreen/yellowPEconnectorin
TB1.
STEP 6 VerifythattheprimaryAClinevoltageiscorrectatthepanelboardormains
serviceentry.MeasuretheprimaryAClinevoltagefromphase‐to‐neutralor
phase‐to‐phaseandrecordforfuturereference.
STEP 7 Verifythatthemeasuredmainsvoltagesinthepreviousstepfallwithinthe
mainsvoltagerangesdiscussedin"2.6ACMainsR
equirements"onpage2‐2.
STEP 8 Replaceaccesspanelremovedinpreviousstep.
STEP 9 Procedurecomplete.
2.9.4 InterlockConnectionsProcedure
TheUAXtransmitterhasprovisionsforthefollowinginterlockloopconnections:
• RFMuteInterlock–inhibitsRFoutputwhenloopisopened,buttransmitterremains
switchedon.RFreturnsassoonasloopisclosedagain.
• SafetyInterlock–transmitterisswitchedoffwhenloopisopened.Onceloopisclosed
again,afreshtransmitter‘on’commandisrequiredtoresumetransmitting.
• EmergencyStop–anoptionallargeredbuttonthatmaybeconnectedtothetransmitter
saf etyinterlockand/oranexternalcustomer‐suppliedACmainscontactor.
TheRFMut
eandSafetyinterlockconnectionsareavailableontheInterlock/RS‐485busthatoriginatesattheLPU
andloopsthroughallexternalPABs.Whenrackintegrationisprovided,theRS‐485busterminatesataUAX/VAX
CUSTI/Opanelattherackroof,andcustomerinterlockconnectionsarema
deatthatpanel.
STEP 1
EstablishthesafetyinterlockandRFmuteconnectionsbyinstallingthe
dummyplugprovidedwiththetransmittercable/accessorykit.
Customer‐suppliedrack:installtheDB‐15jumperplugontheemptyControlBconnectorontheLPU,orifthe
systemcontainsPABs,onthelastPABintheRS‐485/Interlockdaisychain.Figure2‐3showsth
ejumperplugwiththe
safetyin
terlockjumperinstalledbetweenpins2&8.NewermodelUAXtransmittersalsohaveasoftwareenabled
RFmuteinterlockthatisconnectedbetweenpins8&14.
RSt
erminationresistorR22(121shouldbeconnectedbetweenpins8& 9ontheLPUControlBconnector
oronthelastPABControlBconnectorinthesystem .
Harris‐supplie
drack:installthe8‐pinWAGOconnectorwithpins2‐3(SafetyInterlock)and5‐6(RFMute)jumpered
atterminalboardpositionJ2ofthecustomerI/Oboardatthetopofthetransmitterrack.
Vue de la page 49
1 2 ... 45 46 47 48 49 50 51 52 53 54 55 ... 291 292

Commentaires sur ces manuels

Pas de commentaire