Sharp SD-AT1000W Spécifications Page 203

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 292
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 202
Maxiva UAX
October 17, 2013
523
8882693004 WARNING:Disconnectprimarypower priortoservicing.
Copyright©2013,HarrisBroadcast
Figure 5-12 LPU FWD & REF Sample Inputs
Thisva
lueof0dBmalsocorrespondstothehighpointcalibrationvalueforthesystemreflected(REFPWR) input.
Systemreflectediscalibratedoverarangecorrespondingto30dB…10dBreturnloss,whichcorrespondstoreflected
sampleinputsof‐20dBmforthelowpointand0dBmforthehighpointafterfa
ctoringinreflectedcouplingvalue,
cabling,pad,andsplitter(ifinstalled).Thus,reflectedcalibrationcanbeperformedbyraisingthetransmittertofull
outputpowerandtemporarilyconnectingtheLPUFWDsamplecabletothe REFPWRinputthrougha20dB
attenuatorpadforthelowpoint,anddirectly(nopad)fo
rthehighpoint.PleaseseetheSystemReflectedPower
CalibrationSection5.6.3onpage527formoredetailonthisprocedure.
Note
RTAC is disabled during calibration. Power control is automatically switched to manual mode during cal-
ibration.
Figure 5-13 System Calibration
Stored Calibration
Figure 5-14 RTAC Linear/Non-Linear RTAC Stored Correction Sets
Vue de la page 202
1 2 ... 198 199 200 201 202 203 204 205 206 207 208 ... 291 292

Commentaires sur ces manuels

Pas de commentaire