Sharp SD-AT1000W Spécifications Page 188

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 292
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 187
Section-5 Maintenance
October 17, 2013
58
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypower priortoservicing. 8882693004
Note
RTAC precorrection is automatically disabled and power control is automatically switched to manual
mode during calibration.
5.4.2 ForwardCalibrationProcedure
STEP 1 ZeroandcalibrateRMSpowermeterfollowingthemanufacturer’s
proceduresforspecificmodel.
STEP 2 Locatesystemforwardcalibrationsampleport,whichshouldhavebeen
measuredandlabeledatthefactorywiththecouplingfactorforyour
frequencyofoperation.Thiswilleitherbeaforwardportontheprefilter
directionalcoupler,leftavailableforthispurposeinastandalone(i.e.non
racked)configuration,orth
efrontpanelPREFILTERFWD (forward)power
sampleinarackedconfiguration.Ifthecouplingfactorisinquestion,orif
thefrequencyhaschanged,theapplicableforwardcouple rportshouldbe
sweptwithanetworkanalyzertodeterminethecorrectcouplingfactorat
thefrequencyofinterest.Remembertoincludeth
elossintheroutingcables
inthenetworkanalyzermeasurementwhencharacterizingthebulkhead
measurementpoint.
STEP 3 Oncethecouplingvalueisdetermined,enterthisvalueasanoffsetinthe
powermeter,setthemetersdisplaytoreadindBm(3digitsissufficient,i.e.
xx.xdBm),andconnectthemeterssensortothisport.
Note
Please ensure that the sample level present at this point (max system output, in dBm, minus the coupling
factor) does not exceed the maximum input range of power sensor being used.
STEP 4 IfdualLPUsareinusesettheTCUDriverControltoManual.SelecttheLPU
tobecalibratedastheactiveLPU.
STEP 5 PressandholdtheLowerbuttonfor30secondstoreducetransmitterRF
outputatturnon.UsetheTCULowerbuttonfordualsystems.UsetheLPU
LowerbuttonifasingleLPUispresent.
STEP 6 PressTCUOnbuttonifpresent.PressselectedLPUOnbuttonifnoTCUis
presetn.
STEP 7 EntertheForwardcalibrationmenu,eitherfromthefrontpanel(Setup>
XMTRPOWERSETTINGS>POWERCAL>FORWARD)orfromtheWebGUI.
SeeSystemCalibration’(leftside)inFigure53onpage56.
Vue de la page 187
1 2 ... 183 184 185 186 187 188 189 190 191 192 193 ... 291 292

Commentaires sur ces manuels

Pas de commentaire