Sharp SD-AT1000W Spécifications Page 266 : Table 6‐4 MODFPGA Modulation Specific Faults

/ 292
Table des matières
Section-6 Diagnostics
October 17, 2013
6‐10
Copyright ©2013, Harris Broadcast
WARNING: Disconnect primary power prior to servicing.
888‐2693‐004
Modulator No
Timestamp (FF
FFFF)
Indicates timestamp
is missing on valid
input 2
System LED red.
Timestamp is
present
Input is present, but
timestamp is missing on
input 2
Set fault.
Modulator PFRU
Undisciplined
Indicates PFRU PLL is
not disciplined for
DAB
System LED red.
PFRU PLL is
disciplined
PLL is undisciplined AND
dynamic delay on AND
PLL bypass off
Set fault.
Modulator
Unresolved ETI
Timing
Indicates ETI timing
unresolved
System LED red.
Current input = correct
input
Current input = wrong input
Set fault.
DAB: ETI Missing
DAB ETI input
missing
System LED orange.
ETI input 1 and 2
present
ETI input 1 OR ETI input 2
missing
Set warning.
DAB: Seamless
Not Possible
DAB Seamless
switching not
possible
System LED orange.
Total delay of input
1 and 2 are equal,
Status of input 1
and 2 are equal
(total delay of input 1 and
2 are not equal) OR
dynamic delay mode on
AND (input status 1 and 2
are not equal)
Set warning.
Modulator Input
Signal Loss
Indicates required
inputs are not
present in MOD
FPGA.
System and Mute
LEDs red.
Depends on
modulation
standard. Relevant
inputs present.
DAB:
Set fault and
mute RF.
Modulation
Mute
Indicates modulator
FPGA has muted
System and Mute
LEDs red.
Depends on
modulation
standard.
Modulator not
muted, other
conditions ok
DAB:
Software initiated on
reset,
Mute bit set in MOD
FPGA
Set fault and
mute RF.
CTTB (modulation specific)
Modulator Input
A
Indicates input A is
present in MOD
FPGA. ATSC ASI HPA
System LED red. TS
Input LED yellow or
red.
MPEG sync indicator
= 1
MPEG sync indicator = 0
AND
input A selected for
primary or auxiliary input
Set fault.
Modulator Input
C
Indicates input C is
present in MOD
FPGA. ATSC ASI LPB
System LED red. TS
Input LED yellow or
red.
MPEG sync indicator
= 1
MPEG sync indicator = 0
AND
input C selected for
primary or auxiliary input
Set fault.
Modulator Input
B
Indicates input B is
present in MOD
FPGA. ATSC SMPTE A
System LED red. TS
Input LED yellow or
red.
MPEG sync indicator
= 1
MPEG sync indicator = 0
AND
input B selected for
primary or auxiliary input
Set fault.
Modulator Input
D
Indicates input D is
present in MOD
FPGA. ATSC SMPTE B
System LED red. TS
Input LED yellow or
red.
MPEG sync indicator
= 1
MPEG sync indicator = 0
AND
input D selected for
primary or auxiliary input
Set fault.
Modulator Input
Signal Loss
Indicates required
inputs are not
present in MOD
FPGA.
System and Mute
LEDs red.
Depends on
modulation
standard. Relevant
inputs present.
CTTB:
SFN mode AND
unmute_nosig = false
AND selected input not
present
Set fault and
mute RF.
Modulation
Mute
Indicates modulator
FPGA has muted
System and Mute
LEDs red.
Depends on
modulation
standard.
Modulator not
muted, other
conditions ok
CTTB:
Set fault and
mute RF.
ATSC (modulation specific)

Table 6‐4 MODFPGA Modulation Specific Faults

Fault Log
Message
Fault Description
Front Panel LEDs
Nominal Value/
Scaling
Trip Level
Action
Screen/
Tab

Fichier PDF · ·

Imprimer

Imprimer le document

Partage

Questions sur Sharp SD-AT1000W

Pas encore de questions sur ce manuel. Posez la première.

Poser une question

Nous répondons à partir du manuel et indiquons la page. La question est publiée sur le site après vérification.

Toutes les questions et réponses ›