Sharp SD-AT1000W Spécifications Page 266 : Table 6‐4 MODFPGA Modulation Specific Faults
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
Section-6 Diagnostics
October 17, 2013
6‐10
Copyright ©2013, Harris Broadcast
WARNING: Disconnect primary power prior to servicing.
888‐2693‐004
Modulator No
Timestamp (FF
FFFF)
Indicates timestamp
is missing on valid
input 2
System LED red.
Timestamp is
present
Input is present, but
timestamp is missing on
input 2
Set fault.
Modulator PFRU
Undisciplined
Indicates PFRU PLL is
not disciplined for
DAB
System LED red.
PFRU PLL is
disciplined
PLL is undisciplined AND
dynamic delay on AND
PLL bypass off
Set fault.
Modulator
Unresolved ETI
Timing
Indicates ETI timing
unresolved
System LED red.
Current input = correct
input
Current input = wrong input
Set fault.
DAB: ETI Missing
DAB ETI input
missing
System LED orange.
ETI input 1 and 2
present
ETI input 1 OR ETI input 2
missing
Set warning.
DAB: Seamless
Not Possible
DAB Seamless
switching not
possible
System LED orange.
Total delay of input
1 and 2 are equal,
Status of input 1
and 2 are equal
(total delay of input 1 and
2 are not equal) OR
dynamic delay mode on
AND (input status 1 and 2
are not equal)
Set warning.
Modulator Input
Signal Loss
Indicates required
inputs are not
present in MOD
FPGA.
System and Mute
LEDs red.
Depends on
modulation
standard. Relevant
inputs present.
DAB:
Set fault and
mute RF.
Modulation
Mute
Indicates modulator
FPGA has muted
System and Mute
LEDs red.
Depends on
modulation
standard.
Modulator not
muted, other
conditions ok
DAB:
Software initiated on
reset,
Mute bit set in MOD
FPGA
Set fault and
mute RF.
CTTB (modulation specific)
Modulator Input
A
Indicates input A is
present in MOD
FPGA. ATSC ASI HPA
System LED red. TS
Input LED yellow or
red.
MPEG sync indicator
= 1
MPEG sync indicator = 0
AND
input A selected for
primary or auxiliary input
Set fault.
Modulator Input
C
Indicates input C is
present in MOD
FPGA. ATSC ASI LPB
System LED red. TS
Input LED yellow or
red.
MPEG sync indicator
= 1
MPEG sync indicator = 0
AND
input C selected for
primary or auxiliary input
Set fault.
Modulator Input
B
Indicates input B is
present in MOD
FPGA. ATSC SMPTE A
System LED red. TS
Input LED yellow or
red.
MPEG sync indicator
= 1
MPEG sync indicator = 0
AND
input B selected for
primary or auxiliary input
Set fault.
Modulator Input
D
Indicates input D is
present in MOD
FPGA. ATSC SMPTE B
System LED red. TS
Input LED yellow or
red.
MPEG sync indicator
= 1
MPEG sync indicator = 0
AND
input D selected for
primary or auxiliary input
Set fault.
Modulator Input
Signal Loss
Indicates required
inputs are not
present in MOD
FPGA.
System and Mute
LEDs red.
Depends on
modulation
standard. Relevant
inputs present.
CTTB:
SFN mode AND
unmute_nosig = false
AND selected input not
present
Set fault and
mute RF.
Modulation
Mute
Indicates modulator
FPGA has muted
System and Mute
LEDs red.
Depends on
modulation
standard.
Modulator not
muted, other
conditions ok
CTTB:
Set fault and
mute RF.
ATSC (modulation specific)
Table 6‐4 MODFPGA Modulation Specific Faults
Fault Log
Message
Fault Description
Front Panel LEDs
Nominal Value/
Scaling
Trip Level
Action
Screen/
Tab