Sharp SD-AT1000W Spécifications Page 160

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 292
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 159
Section-3 Operation
October 17, 2013
392
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypower priortoservicing. 8882693004
3.8.12 StatusScreens‐CTTB/CMMBModulation
Figure 3-86 LPU CTTB Status Screen 1
Figure 3-87 LPU CTTB Modulator Status Screen 2
Table383XmtrHome>ExciterHome>Status>CTTBModulator(screen1)
Field Explanation
ASIInputLossPrimary Displayonlyshowingthestatusoftheprimarytransportstream(ASI1).Red=lossof
transportstream,Green=transportstreampresent.
ASIInputLossAuxiliary Displayonlyshowingthestatusoftheauxiliarytransportstream(ASI2).Red=lossof
transportstream,Green=transportstreampr
esent.
SIPStatus Displaysstatusofthisparameter.
PowerOnInput Displaystheselectedtransportstream(primaryofsecondary).
ActiveInput Displaystheselectedtransportstream(primaryorsecondary)whichisactive(ontheair).
SwitchingMode PossibilitiesareAutomaticorManual.Displaystheselectedtransportstreamswitchmode.If
intheautomaticmodeandthecurrentASIst
reamhasanissueordropsout,andtheAuxiliary
InputissettoYes,thesystemwillswitchtotheauxiliaryASIstreamifitisavailableandgood.
NetworkOperation DisplaysthenetworkconfigurationmodeMFN(multiplefrequencynetwork)orSFN(single
frequencynetwork).
AuxiliaryInput Indicatesyesorno.Ifyesisse
lectedtheexcitercanbemadetoswitchtoanauxiliaryinputif
theactiveinputfaultsordropsout.
Vue de la page 159
1 2 ... 155 156 157 158 159 160 161 162 163 164 165 ... 291 292

Commentaires sur ces manuels

Pas de commentaire