Section-5 Maintenance
October 17, 2013
554
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypower priortoservicing. 8882693004
)
Figure 5-41 LPU Date and Time Battery Location
Thepartnumberforthedateandtimebatteryis6600093000(CR1032)foroldermodels
and6600054000(CR2032)fornewermodels(shownabove).
5.9.12.1 SettingLPUDateandTimeafterBatteryReplacement
Usethefollowingproceduretosetthedateandtime.
STEP 1
UsethewebbrowsertologintotheLPUusingthefrontorrearEthernet
connectors.
STEP 2 GotoLPUSetup>LPUSetupscreen.
STEP 3 IntheLPUSetupscreen,clickineachbox.
a.
Akeyboardwillappear.Typeinthevalueforthatbox,thenpressenter.
b.RepeatstepAforeachbox.
c.Thetimeisenteredinthe24hourformat.
d.Thisscreendoesnotindicatethecorrecttime.Correcttimeanddateareindicatedinthe
Status>SignalProcessorscreen.
STEP 4
Procedurecomplete.
5.9.13 BatteryBackup(UPSoption)Replacement
ThefollowingproceduredescribesinstallationoftheUAXLPUbatterybackup(UPS)option9710051012G.The
batter ybackupboarddescribediscompatiblewiththe9710051011GASMPowerModulewhichcontainsthe901
0215241GPWA,LVPSDistributionboard.
Thebat
terybackup(UPS)optionisusefulinsystemsthatrequiresynchronizedtimingasinSFNnetworks.TheUPS
batter ypackkeepsmodulatorsectionoperationalforoneminuteandholdovercomponents(clockovenandthe
GPSreceiver)operatingforapproximately15minutesifthebatteriesarefullycharged.