Sharp IQ-8000 Manuel d'installation Page 61

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 125
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 60
6.10 Installing Noise Suppression Devices
Install an MOV or diode (or both) at the lock to suppress noise and avoid problems related to
spikes. Follow the instructions below and refer to the diagrams in section 6.1.
6.10.1 Procedure
The most effective location for a suppression device is at the source; in this case, at the door
strike.
1. Remove the strike-locking device and find the wire connector that attaches the lock wires to
the lock.
2. Install an MOV (Siemens S10K30 or equivalent) in parallel with the load. The MOV is a non-
polarized device and will work with both AC and DC locks.
NOTE Use an additional MOV if you experience further noise at the strike.
NOTE For further protection on DC units, a reverse biased diode may be
installed (We suggest types 1N4004 to 1N4007 be used) also in
parallel with the load.
3. Note the wiring set-up of your particular system. Connections can be made either to the
“normally open” (fail secure) contact or to the “normally-closed” (fail-safe) configuration
whereby an isolation relay is used and a diode (or MOV) is added for noise suppression.
Page xlviii of 110 IQ-400 Installation Manual 33-10057-001-C