Sharp IQ-8000 Manuel d'installation Page 102

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 125
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 101
9.2.3 Door Sense LEDs
4 LEDs located at D17, D18, D19, and D20 indicate the status of the Door circuits. Resistors must be
installed at the door contacts, the switches in place, door closed (normal state), and the lines calibrated,
in order for the supervised inputs to function. See Step 4 for installation and calibration procedure.
LED Status Chart (for IQ-400 firmware I4+07.010.02 series):
Sense Input #25 LED is D17
Sense Input #27 LED is D18
Sense Input #29 LED is D19
Sense Input #31 LED is D20
NOTE LEDs D21-D24 are not used in the IQ-800.
OFF Circuit is in normal/secure state
ON Circuit is in an alarm condition state
Blinks once every 2 seconds Fault condition. Open circuit state
Blinks 1 time/second Fault condition. Short circuit state
Blinks 4 times/second Circuit is NOT calibrated and NOT in a functional state
9.2.4 Four-Reader Expansion Board- Active LEDs (P/N: 03-10102-301E)
4 LEDs located at D61, D62, D67, D68 indicate the status of the Reader circuits. When the LED blinks
momentarily after a card swipe, the system is processing the card data. The LED is normally off.
Reader LED Status:
Reader E LED is D61
Reader F LED is D62
Reader G LED is D67
Reader H LED is D68
9.2.5 Jumpers
Reader type is selected by the use of jumpers located in between the reader ports at W5 and W11-W14.
Refer to each diagram of reader-types on Section 5.0 [Reader Connections] for the proper setting of
these jumpers. Four other jumpers, located at W1, W2, W3, W6 and W15, designate chip selection, and
are set at the factory. They should not be changed unless directed by technical support.
The setting of the four jumpers at W5 (4W or 5W) determines how the jumpers next to each reader port
is set. Also, when using a 5-wire, 12VDC reader, you can control the voltage at PIN 1, by moving the
leftmost jumpers at W5 in conjunction with the reader port jumper setting (see Section 9.11.2 – next
page).
Page lxxxix of 110 IQ-400 Installation Manual 33-10057-001-C