27
6. Assembly
Inserting gas discharge lamps (Hg and Xe) into
the 106/106z lamp housing
Hg and Xe lamps are powered by separate sup-
ply units.
Please also read the separate instruction manu-
al provided with these supply units.
The following gas discharge lamps may be used
and require different power supplies and lamp
mounts (Fig. 19):
Type Typical bulb life*
50 W high-pressure mercury burner (alternating current) 100 hrs.
100 W high-pressure mercury burner (direct current) 200 hrs.
100 W high-pressure mercury burner (direct current, type 103 W/2) 300 hrs.
75 W high-pressure xenon burner (direct current) 400 hrs.
* Please observe the data sheets of the lamp manufacturer.