CHAPTER 2. OPTIONS
1. Sales options
No. NAME MODEL DESCRIPTIONS
1 REMOTE DRAWER ER-04DW 5B/5C
2 COIN CASE ER-55C2 5B/5C
3 KEY TOP KIT ER-11KT7 1 × 1 key top
ER-12KT7 1 × 2 key top
ER-22KT7 2 × 2 key top
ER-11DK7 1 × 1 dummy key
ER-51DK7 5 × 1 dummy key
2. Service options
No. NAME PARTS CODE PRICE RANK DESCRIPTIONS
1 SRV KEY LKGIM7113RCZZ AK
2 MODE KEYGRIP COVER LKGIM7126RCZZ AL OP key only
3 DRIP-PROOF KEYBOARD COVER GCÇVH7126BHZZ BE
4 SHIELD PLATE KIT DKIT-8666BHZZ BL Only for ER-A330
3. Supplies
No. NAME PARTS CODE PRICE RANK DESCRIPTIONS
1 ROLL PAPER DPAPR1006CSZZ AR
2 INK ROLLER (ER-A310) NRÇLR6652RCZZ AZ
3 INK ROLLER (ER-A330) NRÇLR6638RCZZ AY
4 INK FOR STAMP UINK-1001CCZZ AK
CHAPTER 3. SRV RESET AND MASTER RESET
The SRV key is used for operating in the SRV mode.
1. SRV. reset (Program Loop Reset)
Used to return the machine back to its operational state after a lock-
up has occurred.
Procedure
• Method 1
1) Turn off the AC switch.
2) Set the mode switch to (SRV′) position.
3) Turn on the AC switch.
4) Turn to (SRV) position from (SRV′) position.
2. Master reset (All memory clear)
There are two possible methods to perform a master reset.
• MRS-1
Used to clear all memory contents and return machine back to its
initial settings. return keyboard back to default. for default keyboard
layout.
Procedure-1 (with SRV key)
1) Unplug the AC cord from the wall outlet.
2) Set the MODE switch to the (SRV′) position.
3) Plug in the AC cord to the wall outlet.
4) While holding down JOURNAL FEED key, turn to (SRV) position
from (SRV′) position.
Procedure-2 (without SRV key)
1) Turn the mode switch to the (REG) position.
2) Ensure the batteries are not installed in the battery compartment
and insert the plug into the outlet.
3) The right most decimal point will blink for a few seconds.
4) The register will sound three beeps.
5) The register will display " ."
– 6 –