Sharp PN-655U Manuel d'utilisateur Page 46

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 128
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 45
44
E
<Response format in Advanced operation >
When a command has been executed correctly
Response when no ID number has been set
A response is returned when execution of the
pertinent command is finished.
Response when an ID number has been set
When a command has not been executed correctly*
Response when no ID number has been set
Response when an ID number has been set
* This is returned when there is no such command, or when the command cannot be used in the current state of
the monitor.
Example: When “ADJUSTMENT” is used (a command which is effective when the input mode is “ANALOG”),
while video is displayed (the input mode is “VIDEO”).
* If communication has not been established for reasons like a bad connection between the PC and the monitor,
nothing is returned, not even ERR.
* If no monitor has been assigned the designated ID number (e.g. if the command IDSL0002 is used, but no
monitor with ID number: 2 is found), no response is returned.
OK
Return code
(0D
H
, 0A
H
)
OKSPC 0 0 1
ID number of res
p
ondin
g
monitor
Space (20
H
)
Return code
(0D
H
, 0A
H
)
RRE
Return code
(0DH, 0AH)
RRE SPC 0 0 1
ID number
Space (20
H
)
Return code
(0D
H
, 0A
H
)
PC Operation (Continued)