ENGLISH
41
E
<Commands for ID control>
The command examples shown on this page assume the following connection and ID number set up.
IDST......A monitor receiving this command sets its own ID number in the parameter field.
Example: IDST0001
OK
001 The ID number of this monitor is set to 1.
After linking monitors, you can automatically assign ID numbers by using the IDST command with
the Repeater control (see “Repeater control” on page 43).
[Example]
If you connect monitors as shown above, and use the command “IDST001+”, ID numbers will be set
automatically, as shown below.
[Example]
IDST001+ ID setting command with repeater control
WAIT
OK
001 “OK” response from ID number: 1
OK 002 “OK” response from ID number: 2
OK 003 “OK” response from ID number: 3
OK 004 “OK” response from ID number: 4 (End)
Note
PC ID number: 1 ID number: 2 ID number: 3 ID number: 4
PC Set 1 Set 2 Set 3 Set 4
PC ID number: 1 ID number: 2 ID number: 3 ID number: 4