8 - 17
8
Timing chart when operation is performed on one axis at a time started up by X-axis
Time
Speed
X-axis
Step No. enable
(05202)
Program operation
startup
(05200)
0(Continuous)
Positioning
completed(X)
(05001)
Busy flag(X)
(05002)
2
Single-step/continuous
startup setting
(05201)
Time
Speed
Y-axis
Program operation
startup standby(X)
(05003)
Step No.(X)
(49000)
7-segment display LED
shows step No.
2
Busy flag(Y)
(05042)
3
9
15
Output code(X)
(49010)
00
05
01
02
Dwell timer
Dwell timer
Step No. at program
startup
( 0523)