(11) Adjustment volume
No.
Parts
Note
Code Name Function/operation
1 VR1 Scanner lamp light quantity adjustment
volume
Adjusts the scanner lamp light quantity.
2 VR601 Output voltage adjustment volume Adjust the DC output voltage (+24V).
3 VR801 Main charger voltage adjustment volume Adjusts the main charger voltage.
4 VR802 Developing bias voltage adjustment
volume
Adjusts the developing bias voltage.
D. Lock position
No.
Parts
Note
Name Function/Operation
1 Scanner lock screw Locks the scanner unit. Fixes the scanner unit with this screw when in transit.
1)
VR601
VR802
VR801
FO-3800M
5 – 24
Vue de la page 55