showenvironment(8)
284 XSCF Reference Manual Last Revised January 2007
EXTENDED
DESCRIPTION
For some systems, voltage margin is set for each entire system. In such a case, the
voltage margin is displayed along with the value of the voltage sensor.
EXAMPLES
EXAMPLE 1 Displays the intake temperature and humidity of the system.
EXAMPLE 2 Displays temperature information about the system and each component.
XSCF> showenvironment
Temperature:30.71C
Humidity:90.05%
XSCF> showenvironment temp
Temperature:30.71C
CMU#0:30.71C
CPUM#0-CHIP#0:30.71C
CPUM#1-CHIP#0:30.71C
CPUM#2-CHIP#0:30.71C
CPUM#3-CHIP#0:30.71C
CMU#1:30.71C
CPUM#0-CHIP#0:30.71C
CPUM#1-CHIP#0:30.71C
CPUM#2-CHIP#0:30.71C
CPUM#3-CHIP#0:30.71C
CMU#2:30.71C
CPUM#0-CHIP#0:30.71C
CPUM#1-CHIP#0:30.71C
CPUM#2-CHIP#0:30.71C
CPUM#3-CHIP#0:30.71C
CMU#3:30.71C
CPUM#0-CHIP#0:30.71C
CPUM#1-CHIP#0:30.71C
CPUM#2-CHIP#0:30.71C
CPUM#3-CHIP#0:30.71C