Unit Operation
49
CAUTION: The motor may start automatically any time the
unit is turned on.
When the motor is preparing to start, the SR-3 Standard Truck
HMI Control Panel will continue to show the Standard Display
as shown in Figure 28. The preheat buzzer at the unit (located
on the unit Interface Board) sounds for 20 seconds before the
electric motor starts.
Figure 28: Standard Display
Switching from Diesel to Electric
IMPORTANT: Applies to units with the Electric Standby
Option only. The operation of this feature can be changed
using the Guarded Access Menu. See the Guarded Access /
Unit Configuration Menu / Diesel to Electric Auto Switch
Enabled feature in Section 3 of this manual for details. The
Diesel to Electric Auto Switch Enabled feature should be set
YES on units equipped with the Standard Truck HMI Control
panel.
Diesel to Electric Auto Switch Enabled set YES
(Default): If this feature is set YES, the unit will switch
automatically from Diesel Mode to Electric Mode when
standby power is connected and present.
Diesel to Electric Auto Switch Enabled set NO: The
Diesel to Electric Auto Switch Enabled feature should not be
set NO on units equipped with the Standard Truck HMI
Control panel.