3) Pin description
PIN
No.
SYMBOL
SIGNAL
NAME
IN/
OUT
FUNCTION
1
/RES /RESET
IN
RESET INPUT from CKDC WUTH
BUFFER
2
NMi NMi
IN
NON-MASKABLE INTERRUPT
INPUT FOR SSP INTERRUPT INPUT
3 VSS VSS GND
4 P10 ERC OUT EVENT READ CANCEL (to CKDC)
5 P11 LDRQ OUT LOAD REQUEST (to CKDC)
6 P12 /SHEN IN SHIFT ENABLE (from CKDC)
7 P13 /FRES OUT FISCAL MEMORY RESET (Nu)
8 P14 BUSY IN FISCAL MEMORY BUSY (Nu)
9 P15 /RDY IN FISCAL MEMORY READY (Nu)
10 P16 PDS IN POP-UP DISPLAY SENSOR (Nu)
11 P17 IN GND
12 D0 D0 I/O DATA BUS 0
13 D1 D1 I/O DATA BUS 1
14 D2 D2 I/O DATA BUS 2
15 D3 D3 I/O DATA BUS 3
16 D4 D4 I/O DATA BUS 4
17 D5 D5 I/O DATA BUS 5
18 D6 D6 I/O DATA BUS 6
19 D7 D7 I/O DATA BUS 7
20 VSS VSS GND
21 A0 A0 OUT ADDRESS BUS 0
22 A1 A1 OUT ADDRESS BUS 1
23 A2 A2 OUT ADDRESS BUS 2
24 A3 A3 OUT ADDRESS BUS 3
25 A4 A4 OUT ADDRESS BUS 4
26 A5 A5 OUT ADDRESS BUS 5
27 A6 A6 OUT ADDRESS BUS 6
28 A7 A7 OUT ADDRESS BUS 7
29 A8 A8 OUT ADDRESS BUS 8
30 A9 A9 OUT ADDRESS BUS 9
31 A10 A10 OUT ADDRESS BUS 10
32 A11 A11 OUT ADDRESS BUS 11
33 A12 A12 OUT ADDRESS BUS 12
34 A13 A13 OUT ADDRESS BUS 13
35 A14 A14 OUT ADDRESS BUS 14
36 A15 A15 OUT ADDRESS BUS 15
37 VSS VSS GND
38 A16 A16 OUT ADDRESS BUS 16
39 A17 A17 OUT ADDRESS BUS 17
40 A18 A18 OUT ADDRESS BUS 18
41 A19 A19 OUT ADDRESS BUS 19
42 A20 A20 OUT ADDRESS BUS 20
43 A21 A21 OUT ADDRESS BUS 21
44 A22 A22 OUT ADDRESS BUS 22
45 A23 A23 OUT ADDRESS BUS 23
46 VSS VSS GND
47 /WAIT /WAIT IN Wait signal from MPCA
48 /BACK /BACK OUT Bus control request acknowledge
49 /BREQ /BREQ IN Bus control request
50 P33 DOPS IN Drawer open sensor signal
51 P34 /DR0 OUT Drawer open drive signal
52 P35 /DR1 OUT Option drawer 1 drive signal
53 P36 NU IN (Nu) GND
54 P37 NU IN (Nu) GND
55 VCC VCC +5V
56 P40 /IFV IN (Nu) pull-up
57
P41 /PTMG
IN
Printer (PR-45) timing signal from
MPCA
58 P42 /TOF IN (Nu) pull-up
59 P43 /BOF IN (Nu) pull-up
PIN
No.
SYMBOL
SIGNAL
NAME
IN/
OUT
FUNCTION
60
P44 /PRST
IN
Printer (PR-45) Reset signal from
MPCA
61 P45 /NEJ IN Near END signal journal
62 P46 NU IN (NU) GND
63 P47 /NER IN Near END signal receipt
64 VSS VSS GND
65 P50 TRG1 OUT Nu (GND)
66 P51 /PSTOP OUT Nu (GND)
67 P52 /CKDCR2 OUT Nu (GND)
68 P53 OPDS IN Nu (GND)
69 P54 FVPON OUT Nu (GND)
70 P55 FMRS IN Nu (GND)
71 P56 /SLIPLMP OUT Nu (GND)
72 P57 /STOP OUT Nu (GND)
73
P60 /ERS
OUT
ER signal for RS232 (Equipment
Ready)
74 P61 /DRS IN DR signal for RS232 (Data set Ready)
75 P62 /CSS IN CS signal for RS232 (Clear to Send)
76 P63 /CDS IN CD signal for RS232 (Carrier Detect)
77
P64 /RR
OUT
RR signal for RS232 (Ready to
Receive) (Nu)
78
P65 /RSS
OUT
RS signal for RS232 (Request to
Send)
79 P66 (/RI), /CI IN CI signal for RS232 (Calling Indicator)
80 P67 HP IN Nu (GND)
81 VSS VSS GND
82 AVSS AVSS IN GND
83 AN0 Vrf IN Vrf
84 AN1 VHTEST IN VH Test input
85 AN2 VPTEST IN +24V test input
86 AN3 TM IN Thermal head thermistor level test
87 AVCC AVCC IN +5V
88 VCC VCC +5V
89 P80 /iRQ0 IN Interrupt signal 0 from MPCA
90
P81 /iRQ1
(/RSRQ)
IN
Interrupt signal from OPTION PWB
91 P82 /iRQ2 IN Interrupt signal (Nu) pull-up
92 P83 SCK2 OUT CKDC & FMC i/F sync shift clock
93 P84 RXD IN RS232C RECEIVE DATA
94 P85 TXD OUT RS232C SEND DATA
95
P86 RXD2
IN
CKDC, Fiscal memory unit I/F shift
input data
96
P87 TXD2
OUT
CKDC, Fiscal memory unit I/F shift
output data
97 VSS VSS GND
98 EXTAL EXTAL IN X-TAL (19.66MHz)
99 XTAL XTAL IN X-TAL (19.66MHz)
100 VSS VSS GND
101 φφ OUT System clock (9.83MHz)
102 E OUT E clock (NU)
103 /AS /AS OUT Address strobe
104 /RD /RD OUT Read
105 /HWR /WR OUT Write
106 /LWR OUT Nu
107 /RFSH /RFSH OUT Refresh cycle (NU)
108 VCC VCC +5V
109 MD0 MD0 IN +5V (MODE 3)
110 MD1 MD1 IN +5V (MODE 3)
111 MD2 MD2 IN GND (MODE 3)
112 /STBY /STBY IN +5V (Nu)
4 – 4