4
1. INSTALLATION
The mounting method has been verified by SHARP and NOT CERTIFIED
by a third party organization. Please review the descriptions and drawings
carefully; not mounting the modules according to one of these methods may
v
oid your guaranty. These mounting methods are designed to allow module
loading of 2400Pa.
Mounting Using Frame Bolt Holes (Figures 1 & 2)
The modules may be fastened to a support using the bolt holes in the bottom
of the frames at location “C”, as shown in Figure 1 (back view of the module)
and Figure 2 (mounting detail). The module should be fastened with four (4)
M8 bolts. Recommended torque is 12.5 Nm.
M
ounting Using Clips on Long Edge of Module:
L
ong Edge Parallel to Array Rails (Figure 4)
The modules may be mounted using clips (clamps) designed for solar
m
odules as shown in Figures 3 and 4. Note that the clip positions are
i
mportant – the clip centerlines must be between 150mm and 410mm from
t
he end of the module.
The module must be supported along the length of the long edge, and should
o
verlap the array rail by at least 10mm. Note that the mounting clips should
meet the minimum dimensions (catch width of 5mm and length of 38mm) as
shown in Figure 3. The array rails must support the bottom of the frames and
must be continuous pieces (no breaks in the rail).
Mounting Using Clips on Long Edge of Module:
L
ong Edge Perpendicular to Array Rails (Figure 5)
The modules may also be mounted using clips on the long sides of the
module when the array rails are perpendicular to the long sides, as shown in
Figure 5. The clip centerlines must be between 150mm and 410mm from
t
he ends of the module. Note that the mounting clips should meet the
minimum dimensions (catch width of 5mm and length of 38mm) shown in
Figure 3. The array rails must support the bottom of the frames and must be
continuous pieces (no breaks in the rail).
2. ELECTRICAL INSTALLATION INSTRUCTION
C
able characteristics
Conductor size: 4.0mm
2
, Cable type: XLPE cable (CE cable)
Maximum DC voltage: 1.8kV
Ambient temperature: -40°C to +90°C,
Maximum conductor temperature: 120 °C
Module configuration (Recommend)
# Maximum series configuration: please refer to Table 1
(This value is calculated under the condition of Voc at -40 °C.)
# Maximum parallel configuration: (Parallel connection of each string shall
be conducted with following two options. Any other parallel connections are
prohibited.)
a) Case of using the diodes; 1 diode per maximum 2 parallel strings
(Connect a diode or more in series for every string or every 2 parallel
strings for protection of module from reverse current over load.)
b) Case of using the fuses; 1 fuse per every string (Connect a fuse for every
single string for protection of module from reverse current over load.)
Connection cables requirement
The module is fitted with SMK Corporation connectors (CCT9901-
2451F/CCT9901-2361F) which are mechanically and electrically compatible
w
ith Multi-Contact AG (PV-KST4/PV-KBT4) as of 7th April 2011. To extend
the module connecting leads, only use Multi-Contact AG (PV-KST4/PV-
KBT4), or SMK Corporation connectors under the same series.
3. WARNING
Do not stand or step on the PV module (Glass, Frame, Film and Junction
box).
For PV modules with anti-reflective coating glass (NU-R250J5 to NU-R240J5
and ND-R250A5 to ND-R220A5), do not touch the glass since finger prints
or stains will easily mark the glass. If dirt build-up becomes excessive, clean
the glass surface with water only.
N
D-R240A2, ND-R235A2, ND-R230A2, ND-R225A2, ND-R220A2, ND-R215A2, ND-R210A2, ND-R250A5, ND-R245A5, ND-R240A5, ND-R235A5, ND-R230A5, ND-R225A5,
ND-R220A5, ND-235R1J, ND-230R1J, ND-225R1J, ND-220R1J, ND-215R1J, ND-210R1J, NU-R250J5, NU-R245J5, NU-R240J5, NU-235R1H, NU-230R1H, NU-225R1H, NU-220R1H
(Withstand load capability)
F
:
High (< 100kg)
:
Middle (<50kg)
: Low
=
=
Figure 1
Figure 4
F
igure 5
ELECTRICAL OUTPUT AND THERMAL CHARACTERISTICS
Rated electrical characteristics of Isc, Voc, are within ±10 percent of the indicated values and +5/-0 percent of Pmax (power measurement tolerance: ± 3%), under STC (standard test conditions) (irradiance of
1000 W/m2, AM 1.5 spectrum, and a cell temperature of 25 °C (77°F)).
Table-1. Electrical characteristics (at STC)
(*) The maximum series number of modules depends on
the local conditions. These values are calculated under
the condition of Voc at -40 °C.
Under normal conditions, a photovoltaic module is likely
to experience conditions that produce more current
and/or voltage than reported at Standard Test Conditions.
Accordingly, the values of Isc and Voc marked on this
module should be multiplied by a factor of 1.25 when de-
termining component voltage ratings, conductor capaci-
ties, fuse sizes and size of controls connected to the
module output.
Application Class
This module is rated as “Application class A” according to
IEC61730.
“Application class A” means:
General access, hazardous voltage, hazardous power
applications.
Modules rated for use in this application class may be
used in systems operating at greater than 50 V DC or
240 W, where general contact access is anticipated.
Modules qualified as application class A in IEC61730 are
considered to meet the requirements for safety class II.
FIRE RATING
This module is rated as “Fire safety class C” according to
IEC61730.
TINSE0024UNZZ
Model Name Max. Power
(Pmax)
Tolerance Open-Circuit
Voltage (Voc)
Short-Circuit
Current (Isc)
Voltage at Point of
Max. Power (Vmpp)
Current at Point of
Max. Power (Impp)
Max. system
voltage
Over-current
protection
Application
class
Maximum series
configuration(*)
ND-R240A2 240 W +5%/-0% 37.2 8.52 30.4 7.90 1000 V 15 A A 21
ND-R235A2 235 W +5%/-0% 37.1 8.38 30.4 7.74 1000 V 15 A A 21
ND-R230A2 230 W +5%/-0% 37.0 8.24 30.3 7.60 1000 V 15 A A 21
ND-R225A2 225 W +5%/-0% 36.9 8.10 30.3 7.43 1000 V 15 A A 21
ND-R220A2 220 W +5%/-0% 36.8 7.96 30.2 7.29 1000 V 15 A A 21
ND-R215A2 215 W +5%/-0% 36.7 7.82 30.2 7.13 1000 V 15 A A 21
ND-R210A2 210 W +5%/-0% 36.6 7.68 30.1 6.98 1000 V 15 A A 22
ND-R250A5 250 W +5%/-0% 37.6 8.68 30.9 8.10 1000 V 15 A A 21
ND-R245A5 245 W +5%/-0% 37.3 8.62 30.7 7.99 1000 V 15 A A 21
ND-R240A5 240 W +5%/-0% 37.2 8.57 30.4 7.90 1000 V 15 A A 21
ND-R235A5 235 W +5%/-0% 36.8 8.49 30.3 7.76 1000 V 15 A A 21
ND-R230A5 230 W +5%/-0% 36.4 8.41 30.3 7.61 1000 V 15 A A 22
ND-R225A5 225 W +5%/-0% 36.0 8.33 30.2 7.46 1000 V 15 A A 22
ND-R220A5 220 W +5%/-0% 35.6 8.25 30.0 7.35 1000 V 15 A A 22
ND-235R1J 235 W +5%/-0% 36.7 8.44 29.8 7.89 1000 V 15 A A 21
ND-230R1J 230 W +5%/-0% 36.6 8.36 29.5 7.80 1000 V 15 A A 22
ND-225R1J 225 W +5%/-0% 36.6 8.28 29.3 7.68 1000 V 15 A A 22
ND-220R1J 220 W +5%/-0% 36.5 8.20 29.2 7.54 1000 V 15 A A 22
ND-215R1J 215 W +5%/-0% 36.5 8.12 29.0 7.42 1000 V 15 A A 22
ND-210R1J 210 W +5%/-0% 36.4 8.03 28.8 7.30 1000 V 15 A A 22
NU-R250J5 250 W +5%/-0% 37.9 8.76 31.0 8.07 1000 V 15 A A 21
NU-R245J5 245 W +5%/-0% 37.5 8.73 30.5 8.04 1000 V 15 A A 21
NU-R240J5 240 W +5%/-0% 37.3 8.63 30.2 7.95 1000 V 15 A A 21
NU-235R1H 235 W +5%/-0% 37.9 8.49 30.3 7.76 1000 V 15 A A 21
NU-230R1H 230 W +5%/-0% 37.7 8.43 30.0 7.67 1000 V 15 A A 21
NU-225R1H 225 W +5%/-0% 37.5 8.37 29.7 7.58 1000 V 15 A A 21
NU-220R1H 220 W +5%/-0% 37.3 8.31 29.4 7.49 1000 V 15 A A 21
C
C
C
C
INSTALLATION MANUAL - PHOTOVOLTAIC MODULES-
Figure 6
WASHER
SOLAR MODULE
BOLT M8 X 20mm
WASHER
SPRING WASHER
NUT
12
4
3
Figure
2
Figure 3
For your reference, please use the components specified as below for the
m
inimum requirement:
1. Spring washer 2. Washer
Material: Stainless steel Material: Stainless steel
Diameter: M8 8.2/15.4mm Diameter: M8 8.2/15.5mm
Thickness: 2mm(reference value) Thickness: 1.6mm(reference value)
3. Bolt 4. Nut
Material: Stainless steel Material: Stainless steel
Size: M8 Size: M8