Sharp AR-PG1 Spécifications Page 5

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 47
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 4
13) Attach the SPF to the copier.
●
Attach the SPF by inserting the hinge guide sections of the SP3
into the hinge guides L and R.
14) Insert the power plug into the outlet and turn the main switch of
the copier to the “ON” position.
15) Perform SIM setting.
●
Execute simulation [2] of [26] and enter [1].
16) Check the ON/OFF operation of the open detection sensor and
book detection sensor.
●
Execute simulation [2] of [2] and check that the indicator on the
operation panel lights up and goes out by opening and closing
the SPF. When the book detection sensor is turned ON/OFF, the
drum replacement lamp is turned ON/OFF accordingly.
17) Check the copy ratio, and then check the center displacement and
leading edge image void.
●
Place an original on the document glass and make a copy.
Then, place an original in the document feeder tray and make a
copy.
If the center of the copy from the document glass is displaced
from the copyfrom the document feeder, adjust the center refer-
ring to the service manual.
2. AR-FX3 Installation Manual
Turn the main switch to the “OFF” position and remove the power plug
from the outlet.
1) Remove the document cover and the rear cabinet.
●
After removing the document cover, remove the four screws and
then remove the rear cabinet.
1
2
2
Circuit standard label, 1 sheet
AR-SP3
2 – 3