CHAPTER1. SRV RESET (Program Loop Reset) and switch to SRV mode
In the ER-A770, the following reset switch (location No.: SW1) is used
to switch to the service (SRV) mode and to reset.
SRV. reset
Used to return the machine back to its operation state after a lock up
has occurred.
PROCEDURE
1) Turn off the AC switch.
2) Set the reset switch to "ON" position
3) Turn on the AC switch. (Wait one second)
4) Turn to "OFF" the reset switch.
5) The SRV mode is displayed as shown below.
DISPLAY:
Used to reset and resume initial program without clearing memory.
Reset
switch
Rear side :"ON" position(Reset state)
ONOFF
Front side :"OFF" position(Run state)
ONOFF
RESET SW
RESET SW
SW1