Sharp AR-810 Manuel d'utilisateur Page 98

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 101
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 97
AR-651/810 TROUBLE SHOOTING 5 - 98
[CC5] Abnormal horizontal registration motor (with AR-PN3 connected)
Is the horizontal registration home position sensor (PI1P) working normally?
NO
Replace the sensor.
YES
Is the wiring between the horizontal registration home position sensor (PI1P) and finisher controller
PC board correct?
YES
Correct the wiring.
NO
Is the horizontal registration mechanism normal?
NO
Fix the mechanism.
YES
Is the problem solved by replacing the horizontal registration motor (M2P)?
YES
END
NO
Is the problem solved by replacing the punch motor?
YES
END
NO
Is the problem solved by replacing the punch driver board?
YES
END
NO
Replace the finisher controller PC board.
Vue de la page 97
1 2 ... 93 94 95 96 97 98 99 100 101

Commentaires sur ces manuels

Pas de commentaire