Chapter 5 Menu Operation (Edit)
Converts Data in Batch (Program)
(1) Function
The whole program including relay /timer /register /label number are modified in batch.
(2) Operation content
Click [Edit]-[Converts Data in Batch] of the menu bar of the program
[Converts Data in Batch] dialog box will be displayed.
Select the item to convert
Select the kinds (Relay, TMR /CNT, Register, Label) for conversion data in batch.
Setup the address
Setup the start (front) address, end address, the front address of the destination address of the
relay /register, etc.
Select "Is Added /None" of the "Converts Symbol"
In case of changing the symbol/comment at the same time, select "Is Added", and in case of not
changing the symbol/comment, select "None."
If you setup "Is Added," the address of the symbol /comment that attaches to the address will
also be changed at the same time.
Click [Exec.] button.
Data in batch are changed.
(3) Conversion example
Items to convert Relay
Start address 100
End address 101
Destination 200
Converts symbol
None
Converts data
in batch
After the Conversion
Before the Conversion