Sharp UP-810F Manuel d'utilisateur Page 15

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 55
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 14
UP-810F/820N/820F(U) SRV MODE PROGRAMMING (“SETTING”)
3 – 8
907-C: 1. In case of all server or transaction CCD, X report before CCD
entry
2. Minus department / PLU / UPC (EAN)
907-D: 1.
CCD compulsory
[JOB#908] : MRS=0000
908-A: GT print on Z report
908-B: GT print on X report
908-C: 1. Addition to the hourly total in void mode
2. Resetting of consecutive number in Z1
908-D: 1. Printing of X/Z report
(Excepting the individual server report)
2. Z1 resetting that resets GT
[JOB#909] : MRS=2000
909-A: 1. Printing of Training GT on the X report
2. Printing of Training GT on the Z report
909-B: 1. Printing of data on PLU/UPC resetting report
909-C: 1. Printing of VOID mode & MGR VOID in Z2 report
2. Printing of VOID mode & MGR VOID in Z1 report
909-D : Not used (Fixed at “0”)
[JOB#910] : MRS=0024
910-A: 1. Drawer open at server sign ON/OFF
910-B: Not used (Fixed at “0”)
910-C: 1. Server # entry system
910-D: Server system (Fixed at “4”)
1. In case of all
server or trans-
action CCD, X
report before
CCD entry
2. Minus depart-
ment / PLU /
UPC (EAN)
907-C Flat Normal
Disable
Disable 0
Enable 1 ★★
Enable
Disable 2
Enable 3
1. CCD compulsory 907-D Flat Normal
Non-compulsory 0 ★★
For individual server 1
For all server 2
GT1 (NET) GT2 (+) GT3 (-) 908-A Flat Normal
Print
Print
Print 0 ★★
Skip 1
Skip
Print 2
Skip 3
Skip
Print
Print 4
Skip 5
Skip
Print 6
Skip 7
GT1 (NET) GT2 (+) GT3 (-) 908-B Flat Normal
Skip
Skip
Skip 0 ★★
Print 1
Print
Skip 2
Print 3
Print
Skip
Skip 4
Print 5
Print
Skip 6
Print 7
1. Addition to the
hourly total in
void mode
2. Resetting of con-
secutive number
in Z1
908-C Flat Normal
No
No 0 ★★
Yes 1
Ye s
No 4
Yes 5
1. Printing of X/Z
report
(Excepting the
individual server
report)
2. Z1 resetting that
resets GT
908-D Flat Normal
Receipt & Journal
Disable 0 ★★
Enable 1
Journal only
Disable 4
Enable 5
1. Printing of Train-
ing GT on the X
report
2. Printing of Train-
ing GT on the Z
report
909-A Flat Normal
Skip
Print 0
Skip 1
Print
Print 2 ★★
Skip 3
1. Printing of data on PLU/UPC resetting
report
909-B Flat Normal
Print 0 ★★
Skip 4
1. Printing of VOID
mode & MGR
VOID in Z2
report
2. Printing of VOID
mode & MGR
VOID in Z1
report
909-C Flat Normal
Print
Print 0 ★★
Skip 2
Skip
Print 4
Skip 6
1. Drawer open at server sign ON/OFF 910-A Flat Normal
No 0 ★★
Ye s 2
1. Server # entry system 910-C Flat Normal
Stay down 0
Auto sign OFF 2 ★★
Vue de la page 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 54 55

Commentaires sur ces manuels

Pas de commentaire