Sharp CV-P09FR Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Climatiseurs mobiles Sharp CV-P09FR. CV-P09FR Operation-Manual GB Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 22
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
ENGLISH
CV-P09FR
R
* Plasmacluster is a trademark of SHARP
Corporation.
FRANÇAIS
Uses ozone layer friendly refridgerant R410A.
Verwendet das die Ozonschicht schonende
Kühlmittel R410A.
Utilise un réfrigérant qui n’attaque pas la couche
d’ozone, le R410A.
Utilizza il refrigerante R410A che non danneggia
lo strato d’ozono.
Utiliza refrigerante R410A que no daña la capa
de ozono.
• Gebruikt de ozon-vriendelijke koelvloeistof
R410A.
DEUTSCH
ITALIANO
ESPAÑOL
NEDERLANDS
ENGLISH
PORTABLE TYPE
ROOM AIR CONDITIONER
INSTALLATION AND
OPERATION MANUAL
ENGLISH
CONDIZIONATORE D’ARIA
TIPO PORTATILE
MANUALE PER L’INSTALLAZIONE
E IL FUNZIONAMENTO
ENGLISH
CLIMATISEUR MOBILE
MANUEL D’INSTALLATION ET
D’UTILISATION
PORTABLES
RAUMKLIMAGERÄT
INSTALLATIONS- UND
BEDIENUNGSHANDBUCH
DRAAGBAAR TYPE
KAMER-AIRCONDITIONER
INSTALLATIE- EN
GEBRUIKSAANWIJZING
ACONDICIONADOR DE AIRE DE
HABITACIÓN TIPO PORTÁTIL
MANUAL DE INSTALACIÓN
Y FUNCIONAMIENTO
Vue de la page 0
1 2 3 4 5 6 ... 21 22

Résumé du contenu

Page 1 - CV-P09FR

ENGLISHCV-P09FRR* Plasmacluster is a trademark of SHARPCorporation.FRANÇAIS• Uses ozone layer friendly refridgerant R410A.• Verwendet das die Ozonschi

Page 2

The exhaust hose must be installed or removed in accordance with the usage mode. Mode Exhaust hose COOL, FAN, VENTILATION Install DEHUMIDIFICATION

Page 3 - IMPORTANT SAFETY INSTRUCTIONS

ENGLISH13COOL MODEDrainage nozzleStopcockE-9Install the exhaust hose (See Page 8), turn the drainage nozzle to the CLOSEposition, and check the draina

Page 4

DEHUMIDIFICATION MODEE-1076In this mode, the air conditioner dehumidifies the room.Drainage nozzleStopcockHose clampHose1Remove the exhaust hose (See

Page 5 - INCLUDED

ENGLISHFAN MODE1523VENTILATION MODE14523E-11Install the exhaust hose (See Page 8), turn the drainage nozzle to the CLOSEposition, and check the draina

Page 6 - PART NAMES

TO CHANGE AIR FLOW DIRECTIONUP/DOWN AIR FLOW DIRECTIONNOTE• During VENTILATION mode, UP/DOWN air flowdirection cannot be changed.Hold the vertical lou

Page 7 - REMOTE CONTROL DISPLAY

ENGLISHE-131Press the TURBO COOL button during coolingmode.• The remote control will display “ ” .• The temperature display will go off.• The green

Page 8 - USING THE REMOTE CONTROL

0.5h 1.0h 1.5h 10h 11h 12hE-14NOTES ON TIMER SETTING AND OPERATION• The latest time setting will be memorized and will appear on the remote control di

Page 9 - HOW TO USE THE REMOTE CONTROL

ENGLISHE-151ON TIMERDisplay shown when you setthe unit to turn on 6.5 hourslater.The unit will turn on automatically according to your setting.Timer d

Page 10 - Removal of the exhaust hose

AUXILIARY MODEAUXILIARY MODE1E-16Use this mode when the remote control is not available.1Press the AUX. button on the unit.• The red OPERATION lamp (

Page 11 - COOL MODE

ENGLISHDRAINAGEPrepare for drainage and drain out water within the unit in the following cases.If the unit stops operating and the TIMER ( ), OPERATI

Page 12 - DEHUMIDIFICATION MODE

A. Information on Disposal for Users (private households) 1. In the European Union Attention: If you want to dispose of this equipment, please d

Page 13 - VENTILATION MODE

CLEANING THE UNIT AND THE REMOTE CONTROLWipe them with a soft, dry cloth or with a cloth moistened with a mild soap. Carefully removeany residue by wi

Page 14 - TO CHANGE AIR FLOW DIRECTION

ENGLISHBEFORE CALLING FOR SERVICEIf the unit appears to be malfunctioning, check the following points before calling fora service.AIR CONDITIONER DOES

Page 15 - ONE-HOUR OFF TIMER

ENGLISHSHARP CORPORATIONOsaka, JapanTINSEA419JBRZ 05AO TH 1Printed in ThailandR

Page 16 - 0.5h 1.0h 1.5h 10h 11h 12h

ENGLISHENGLISHThis manual explains the proper use of your new air conditioner. Please read this manualcarefully before using the product. This manual

Page 17 - ON TIMER

USAGE CAUTIONS• Ventilate the room periodically during use, especially if using gas appliances.• Be sure to turn the unit off and disconnect the power

Page 18 - PLASMACLUSTER OPERATION

ENGLISHE-3ENERGY EFFICIENCY TIPS• Avoid direct sunlight.Close blinds, drapes or shades to keep out direct sunlight while in cooling mode.• Keep the fi

Page 19 - DRAINAGE

PART NAMES1 Air Outlet2 Vertical louvers3 Horizontal louvers4 PLASMACLUSTER Lamp (blue)5 Remote control signal receiverwindow6 AUX. Button7 OPERATION

Page 20 - MAINTENANCE

ENGLISHREMOTE CONTROL1 Transmitter2 Display3 ON/OFF Button4 DISPLAY Button5 TEMPERATURE Button6 PLASMACLUSTER Button7 1 hr OFF Button8 MODE Button9 ON

Page 21 - BEFORE CALLING FOR SERVICE

1Remove the battery cover at theback of the remote control.2Insert batteries into the com-partment, making sure the ±±±±±and ————— polarities are corr

Page 22 - Osaka, Japan

ENGLISHE-7CAUTION• Do not expose the signal receiver window to direct sunlight. This may adverselyaffect its operation. If necessary, close the curtai

Commentaires sur ces manuels

Pas de commentaire