Sharp FO-DC600 Manuel de service Page 12

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 150
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 11
FO-DC600U
E) Aging mode
This is a mode to execute the copying action and the check pattern
printing action once every 60 minutes and continue the action until 10
sheets are outputted in total.
The printing action on the 1st sheet starts by pressing down the
START key and entering the mode. When document is set at the
time of the mode start-up the copy action is carried out, and when
the document is not set the check pattern 1 of the print dialog is
printed.
The number of printouts is displayed after printing.
F) Panel check mode
This is to check that each key acts normally and this is displayed on the
LCD according to the key input. And during execution, the document
reading lamp is ON. After inspection start, the LEDs light on sequentially.
At the mode end with the STOP key, all of them go OFF. As to the test
result, it is printed out after the mode end.
When the NUMERIC key is pressed during the panel check ex-
ecution, sending of the DTMF signal corresponding to the key starts,
and when another key is pressed sending of the DTMF signal stops.
(Softswitch change is required. SW80 No.6: 0 1)
After inputting all the keys, input the STOP key at last, and then the
result is displayed.
a) In case that all the keys are pressed.
Until the STOP key is pressed, all black 4-split sequential display is
performed.
After the mode end, the test result is printed.
b) In case that there is a key that is not pressed.
Until the STOP key is pressed, all black 4-split sequential display is
performed.
After the mode end, the test result is printed.
G) Optical adjust mode
The optical system is adjusted.
By pressing down the START key, the document reading lamp 100%:
ON is turned ON.
H) Product check
This is a dialog used in the production process and a mode to execute a
specific mode in the series of the flow.
After the mode end, the rest result as to the checked items is printed.
After moving to the mode, the following actions are sequentially ex-
ecuted.
Memory clear (Same as Diagnosis K)
Panel check (Same as Diagnosis F)
ROM & RAM test check (Same as the Diagnosis C)
Test result print
Memory clear printing
Panel check result printing
ROM & RAM test result printing
Print area (The specification of each item is the same as the specifi
cation of the simple mode.)
I) Signal send mode
It can be used to check the modem.
When the START key is pressed, silence signal (make loop) will be
executed. The following signals are sent by pressing the START key
thereafter.
[ 1] No signals (make loop)
[ 2] 4800BPS (V. 27ter)
[ 3] 14400BPS (V. 33)
[ 4] 12000BPS (V. 33)
[ 5] 14400BPS (V. 17)
[ 6] 12000BPS (V. 17)
[ 7] 9600BPS (V. 17)
[ 8] 7200BPS (V. 17)
[ 9] 9600BPS (V. 29)
[10] 7200BPS (V. 29)
[11] 4800BPS (V. 29ter)
[12] 2400BPS (V. 29ter)
[13] 300BPS (FLAG)
[14] 2100Hz (CED)
[15] 1100Hz (CNG)
J) Comm. check mode
Turn on the Line Monitor. (SW7 No.7, SW29 No.7)
Turn off the Cover Sheet Function. (SW2 No.6, SW24 No.6)
Set Line Equivalence at 0 km. (SW8 No.1/No.2, SW30 No.1/No.2)
Set the copy cut off mode (SW75 No.2) to Continue
Set the ringer volume (SW62 No.5/No. 6) to OFF.
After the check, it is necessary to be sure to return the aforementioned
soft switches into the initial state.
(Clear the memory with the diagnosis.)
K) Memory clear mode
Clear the back-up memory to initialize the soft switches.
The Flash Memory will be initialized. Then, the initialized list be output.
Memory clear is executed.
The result that says initialized is printed.
NOTE: The life counter, and the adjustment values of the top void and
the large LCD contrast are not cleared.
2 4
PANEL CHECK MODE
ALL KEY OK !!
PANEL CHECK MODE
KEY ERROR !!
L) Flash Memory check
This is a mode to check that the flash memory acts normally. The flash
memories shown in the following table are checked.
NAND-Flash (optional) is valid only when the optional memory is
mounted.
The NOR flash memory test is executed.
The concerned alarm buzzer sounds only when the error occurs.
The NAND flash memory test is executed.
The concerned alarm buzzer sounds only when the error occurs.
The result is printed.
NOTE:
During operation of this diagnosis, dual operation is not possible at all.
If this is excessively repeated, it will shorten the life of the flash memory.
NOR FLASH CHECK
S E
No. Flash memory
Number of buzzer sound
Remarks
1
NOR-Flash (Standard)
<Long sound> 1 time <Short sound>:
2
NAND-Flash (Standard)
<Long sounds> 2 times
0.5 sec.ON / 0.5 sec.OFF
3
NAND-Flash (Option)
<Long sounds> 3 times <Long sounds>:
4 ——1.0 sec.ON / 0.5 sec.OFF
5 ——
NAND FLASH CHECK